SHANGHAI MICROCRE OPTICS-MECH TECH CO., LTDAbout MICROCRE400-812-7833
AXQ-50 · 1
AXQ-50 · 2
AXQ-50 · 3
3D turntable
1 / 3
MODEL · AXQ-50

AXQ-50 · Mounting presses

Explore the original technical specifications, related methods and configuration options. Chinese source specifications are retained for accuracy.

Product description

适用于所有材料(热固性和热塑性)的热镶嵌;程控式智能操作(温度、时间、冷却等)并可根据实际情况选择合适的制样规格.也可选购可更换钢模套机型。本机配备4种规格Φ25mm、Φ30mm、Φ40mm、Φ45mm(可更换钢模套型φ25mm,

φ30mm, φ40mm, φ45mm)。

Specifications

ParameterValue / description
No.Model | AXQ-50 | AXQ-50 | AXQ-50 | AXQ-50 | AXQ-50( can more 换钢模套)
10Pressure range | 0-2MPA(specimen preparation压强0-72MPA)
11Heating time | 0-99分(Adjustable)
12Tank capacity | 60L
ModelAXQ-50
AXQ-50AXQ-50
Specimen specificationφ25mm
Φ30mmΦ40mm
Φ45mmφ25mm, φ30mm,
φ40mm,φ45mm2
Floor-standing integrated design3
Automatic4
自动(循环水冷,自动定时)8
Heater specification1600W
Temperature rangeAmbient-300℃
Pressure range0-2MPA(specimen preparation压强0-72MPA)
Heating time0-99 minutes (adjustable)
Tank capacity60L
Specifications, options and final delivery conditions follow the confirmed technical agreement and factory documents; verify any model discrepancy with an engineer.

Related methods & standards

Metallographic preparation: five steps to preserve the microstructure ↗Cutting burn control on hardened steel: method essentials and limits ↗Distortion-free sectioning of sheet and foil: method essentials and limits ↗Retaining coating edges in cross-section: method essentials and limits ↗Mounting and chamfering of thermal-spray coatings: method essentials and limits ↗Vacuum impregnation of porous materials: method essentials and limits ↗Avoiding smearing between composite plies: method essentials and limits ↗Preventing scratches and embedded abrasive in soft metals: method essentials and limits ↗Diamond polishing of ceramics and cemented carbide: method essentials and limits ↗Electrolytic polishing of aluminium alloys: method essentials and limits ↗Avoiding hydrogen pickup in titanium preparation: method essentials and limits ↗Sectioning across weld zones: method essentials and limits ↗Measuring heat-affected zone width: method essentials and limits ↗Preparation for grain size measurement: method essentials and limits ↗Consistency for inclusion rating: method essentials and limits ↗Preserving graphite morphology in cast iron: method essentials and limits ↗Porosity preparation for additive parts: method essentials and limits ↗Cross-sectioning of battery electrodes: method essentials and limits ↗Ion-beam polishing of semiconductor cross-sections: method essentials and limits ↗Petrographic thin section preparation: method essentials and limits ↗Protecting fracture surfaces during sectioning: method essentials and limits ↗Reproducible automatic polishing parameters: method essentials and limits ↗Effect of preparation quality on hardness: method essentials and limits ↗Consumable selection and cost control: method essentials and limits ↗Preparation safety and waste handling: method essentials and limits ↗

GB / Chinese standards

GB/T 13298-2015 ↗

ISO

Confirm the applicable method and standard.

Topic-based references do not certify this model or establish full conformity. Confirm the applicable edition, configuration and test conditions.

SCIENCE / AXQ-50

Explore research with this instrument.

Open series research profile ↗

Scientific detail below is the Chinese source edition; reviewed full translations are pending.

Series-level guidance · Sample preparation · Confirm model capabilities, accessories and specifications.

Working principle & animation

The specimen is embedded by hot pressing, cold curing or a specified curing method to support clamping, edge retention and the viewing direction. The curing route must match the heat and pressure resistance of the material.

The schematic explains the basic mechanism; it is not a structural drawing of this model, an operating instruction or a measured result.

Mounting support and edge protection

Schematic model, not device footage or experimental data.

Different resins and curing methods cannot share a single temperature–pressure program
  • Methods and models apply only under the confirmed specific model, accessories and sample conditions.

Research objects & questions

  • Small metallographic specimens
  • Coating cross-sections
  • Edge-sensitive specimens
  • Does mounting alter the microstructure, cause cracking, or penetrate pores?
  • Can the observation face and orientation be reliably preserved?

Testing & operation workflow

Follow inputs, actions, outputs and quality gates.

  1. 01

    Define the object and outcome

    Define the research questions: Does mounting alter the microstructure, cause cracking, or penetrate pores?; Can the observation face and orientation be reliably preserved? Record sample identity, target results and required configuration in the test plan.

    Input
    Sample information, technical drawings / study protocol and documentation for this model
    Output
    A record specifying the object, outcome definition and available configuration
    Quality check
    Required functions are evidenced in the specific model and accessories; unverified functions remain to be confirmed
  2. 02

    Prepare samples and conditions

    Clean and dry the specimen, determine the section orientation, and assess heat, pressure and solvent sensitivity.

    Input
    Defined research object and sample information
    Output
    Traceable samples and preparation conditions
    Quality check
    Material compatibility confirmed
  3. 03

    Check references and equipment

    Check the mold, seals and temperature/pressure control, or the cold-curing mixing tools.

    Input
    Prepared samples, reference specimens and equipment records
    Output
    Verification records and availability status
    Quality check
    Mould and control system in normal condition
  4. 04

    Establish the method and procedure

    Select a suitable resin and curing route; record the batch number and process conditions.

    Input
    Verification results and actual available configuration
    Output
    Saved conditions, parameters and termination rules
    Quality check
    Do not apply hot-mounting conditions to cold-mounting resins
  5. 05

    Execute and save raw records

    After fixing the orientation, mount, cure and cool, avoiding movement, bubbles and premature demoulding.

    Input
    Approved test procedure and quality control settings
    Output
    Raw data, process conditions and anomaly records
    Quality check
    Fully cured and specimen orientation unchanged
  6. 06

    Review results and model

    Check edge gaps, cracks and mounting bubbles; mark the orientation before grinding and polishing.

    Input
    Raw signals, reference data and method definition
    Output
    Results with applicability limits and review records
    Quality check
    No shrinkage gaps at the interface affecting observation
  7. 07

    Archive and reproduce

    Archive the sample ID, model/accessories, raw records, processing version and anomaly handling with cross-references. Re-measure under identical conditions or check disputed results against the reference method.

    Input
    Reviewed results, raw records and configuration list
    Output
    Traceable research/process records and follow-up verification items
    Quality check
    Teaching calculations, demonstration simulations and real measured data are clearly distinguished; unverified items in the materials are not presented as performance commitments.

Workflows & applications

  • Application: small metallographic specimens; Research objective: Does mounting alter the microstructure, cause cracking, or penetrate pores?
  • Application: coating cross-sections; Research objective: Can the observation face and orientation be reliably preserved?
  • Application: edge-sensitive specimens; Research objective: Does mounting alter the microstructure, cause cracking, or penetrate pores?

Methods & standards

  • Preparation of metallographic specimens

Verify the edition, specimen and configuration. Links do not constitute certification or a conformity claim.

Calculations & simulation

Such devices or accessories do not necessarily produce an independent measurand. First use the workflow below to confirm the calculation object, calibration basis and input units, then use the relevant reference tools.

Reference calculations ↗

Scientific literature connection

Links indicate related methods or research objects, not evidence that a paper used our instruments.

Resources, service & limits

  • Check the mold, seals and temperature/pressure control, or the cold-curing mixing tools.
  • Do not apply hot-mounting conditions to cold-mounting resins
  • Verify the delivered model, required accessories, method scope and raw data output; do not infer performance from the series name.
  • Hot, cold and UV mounting are different routes; verify model by model.
  • This dossier covers principles and research workflow; the absence of a measuring-range statement on the page does not mean the device has no limits: the specific range and configuration are subject to technical verification.

Related industry research

Similar instruments

Other models in Mounting presses and the same instrument family.

Browse the whole family ↗

Your next research question. Let’s explore.

Tell us about your material, specimen and measurement goal.

Discuss your application ↗
Find your instrument
⌕
Search products, cases, solutions, standards and literature.