SHANGHAI MICROCRE OPTICS-MECH TECH CO., LTDAbout MICROCRE400-812-7833
CASES

Thermal shock resistance at high ramp rate: worked example

Worked example · not customer test evidence

Objective

Show how Thermal shock resistance at high ramp rate is obtained under hydrogen reducing atmosphere and where the error comes from.

Material

ZTA zirconia-toughened alumina (assumed grade and condition)

Context

Used for internal training and plan review; inputs are assumed and do not represent a customer product or acceptance decision.

Example data

Item

Translation pending review.

测得量

Value

13.24

Unit

1

Item

Translation pending review.

修正量

Value

0.265

Unit

1

Item

Translation pending review.

重复次数

Value

3

Unit

1

Calculation steps

Equation

x̄ = (x₁ + x₂ + x₃)/3

Substitution

(13.24 + 13.77 + 13.5)/3

Result

13.505

Unit

1

Interpretation

The result compares positions or processes within one batch; it is not a stand-alone acceptance decision.

Limitations

Equipment bias and environmental gradients are excluded

Too few replicates to estimate process capability

Workflow & steps

01

Define the environment envelope and coupled fields

Turn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.

02

Check thermal match of system and specimen

Prepare specimens or measurement points for the material and purpose: confirm the temperature limits of furnace, grips, sensors and specimen, evacuate or purge and stabilise before loading, and control heating and cooling rates.

03

Establish vacuum or atmosphere

Verify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.

04

Ramp and stabilise temperature

Execute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.

05

Load and acquire multi-field signals

Judge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.

06

Assess environment-induced bias

Report method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.

Related instruments & resources

Links support navigation and do not establish a model’s performance or standards compliance.

Your next research question. Let’s explore.

Tell us about your material, specimen and measurement goal.

Discuss your application ↗
Find your instrument
⌕