SHANGHAI MICROCRE OPTICS-MECH TECH CO., LTDAbout MICROCRE400-812-7833
METHODS

Leeb hardness in the field and conversion checks: method essentials and limits

Test plan for "Leeb hardness in the field and conversion checks". Specimens of AlSi10Mg die-cast aluminium are measured under high pressure 10 MPa at 1200 °C following hardness testing. The plan fixes sampling, measurement parameters, acceptance basis and record format, and reports temperature uniformity and control deviation with explicit limits of interpretation.

Reporting requirements

Method name and standard edition

Sampling location, specimen condition and count

Environment, equipment and calibration status

Result, dispersion, uncertainty and decision

Common misconceptions

Reusing historical data from a similar material while ignoring batch and process differences

Reporting only a mean value without dispersion, repeatability or uncertainty

Workflow & steps

01

Fix the hardness scale and criterion

Turn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.

02

Prepare and inspect the surface

Prepare specimens or measurement points for the material and purpose: grind and polish the surface without overheating or cold work; keep faces parallel and at least ten indentation depths thick.

03

Verify test force and indenter

Verify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.

04

Space indents and measure

Execute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.

05

Handle outliers and statistics

Judge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.

06

Report values and decision

Report method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.

Checks

  • • The acceptance basis traces to a standard clause or technical agreement
  • • Environmental conditions and stabilisation time are logged continuously
  • • Raw data, processing and the decision are reproducible

Illustrative example

Teaching example: use AlSi10Mg die-cast aluminium measured under high pressure 10 MPa at 1200 °C to show the record format and decision flow; values are assumed, not customer measurements.

Related instruments & resources

Links support navigation and do not establish a model’s performance or standards compliance.

Your next research question. Let’s explore.

Tell us about your material, specimen and measurement goal.

Discuss your application ↗
Find your instrument
⌕
Search products, cases, solutions, standards and literature.