SHANGHAI MICROCRE OPTICS-MECH TECH CO., LTDAbout MICROCRE400-812-7833
MICROCRE · RESEARCH SCIENCE

冲击试验机 — Crack growth rate da/dN

A schematic of the measurement chain, not device footage or data.

Schematic demonstration: scale, speed and colour do not represent instrument measurements.

Translation pending review.

Instrument role

Measurement and analysis

Operating principle

Principle summary

For this task the 冲击试验机 family measures as follows: Crack growth rate da/dN. The general relation and its conditions are given below; confirm force, travel, resolution and accessories for a specific model.

Equation

e = λ / (2 n sinθ)

Variables and units
  • Symbol

    lam

    Item

    Wavelength

    Unit

    nm

  • Symbol

    n

    Item

    Refractive index

    Unit

    1

  • Symbol

    alpha

    Item

    Interference angle

    Unit

    arcsec

Assumptions and limits
  • Conditions are stable and calibrated as defined

  • Inputs are independent without unmodelled bias

  • Interpretation stays within this family and the stated conditions

Research objects

  • Research object: fused silica

  • Research object: BK7 optical glass

  • Research object: sapphire window

Research questions

  • What dominates the error budget for Crack growth rate da/dN?

  • Does the conclusion hold for another batch or process?

Applications

  • Crack growth rate da/dN: TC4 titanium alloy

  • Crack growth rate da/dN: TA15 titanium alloy

From specimen to result

  1. 01
    Title

    Fix the property, method and standard

    Action

    Turn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.

    Input

    Previous output

    Output

    Step 1 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  2. 02
    Title

    Machine and measure specimens

    Action

    Prepare specimens or measurement points for the material and purpose: machine specimens to the standard, measure actual dimensions, align the grips, preload and then load at the specified rate while recording force, displacement and time.

    Input

    Previous output

    Output

    Step 2 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  3. 03
    Title

    Align grips and mount the extensometer

    Action

    Verify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.

    Input

    Previous output

    Output

    Step 3 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step
  4. 04
    Title

    Load at the specified rate and acquire

    Action

    Execute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.

    Input

    Previous output

    Output

    Step 4 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  5. 05
    Title

    Check failure mode and validity

    Action

    Judge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.

    Input

    Previous output

    Output

    Step 5 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  6. 06
    Title

    Compute properties and report

    Action

    Report method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.

    Input

    Previous output

    Output

    Step 6 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step

Methods and standards

  • mechanical property testing

  • Confirm force, range and threshold against the applicable standard

Standards and applicability

  • GB/T 229-2020

  • GB/T 8363-2018

  • GB/T 6803-2008

  • GB/T 5482-2007

  • GB/T 19748-2019

Configuration and service checks

  • Calibration and intermediate check records

  • Fixtures, accessories and range confirmation

Limitations

  • Family-level guidance, not a specific model capability

  • Re-confirm method and criteria outside the stated conditions

Search terms

  • SHPB

  • 霍普金森

  • 高速疲劳

  • 低温力学

  • 多物理场

  • 材料力学试验

  • 试验机

  • 疲劳

  • 冲击

  • 航空航天

Related instruments, methods and research

Paper links indicate related methods or objects; they do not establish use of this instrument model.

Relation commonly used for this task

Your next research question. Let’s explore.

Tell us about your material, specimen and measurement goal.

Discuss your application ↗
Find your instrument
⌕
Search products, cases, solutions, standards and literature.