投影仪 — Positioning accuracy of a precision stage
A schematic of the measurement chain, not device footage or data.
Schematic demonstration: scale, speed and colour do not represent instrument measurements.
Translation pending review.
Instrument role
Measurement and analysis
Operating principle
For this task the 投影仪 family measures as follows: Positioning accuracy of a precision stage. The general relation and its conditions are given below; confirm force, travel, resolution and accessories for a specific model.
L₂₀ = L (1 − α(T − 20))
- Symbol
L
ItemMeasured length
Unitmm
- Symbol
alpha
ItemCTE
Unit1e-6/K
- Symbol
T
ItemPart temperature
Unit°C
Conditions are stable and calibrated as defined
Inputs are independent without unmodelled bias
Interpretation stays within this family and the stated conditions
Research objects
Research object: SiC power device solder layer
Research object: copper lead frame
Research object: electronic solder joint
Research questions
What dominates the error budget for Positioning accuracy of a precision stage?
Does the conclusion hold for another batch or process?
Applications
Positioning accuracy of a precision stage: Ti-6Al-4V additively manufactured part
Positioning accuracy of a precision stage: AlSi10Mg die-cast aluminium
From specimen to result
- 01Title
Read the drawing, datum and tolerance
ActionTurn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.
InputPrevious output
OutputStep 1 record
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn and re-check
- 02Title
Clean and thermally soak the part
ActionPrepare specimens or measurement points for the material and purpose: soak to 20 °C and clean the surface, establish the datum and frame, calibrate the probe, then choose points and evaluation rules from the drawing.
InputPrevious output
OutputStep 2 record
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn and re-check
- 03Title
Calibrate probe or transducer
ActionVerify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.
InputPrevious output
OutputStep 3 record
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn and re-check
- 04Title
Acquire points as planned
ActionExecute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.
InputPrevious output
OutputStep 4 record
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn and re-check
- 05Title
Fit features and evaluate tolerance
ActionJudge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.
InputPrevious output
OutputStep 5 record
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn and re-check
- 06Title
Review outliers and report
ActionReport method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.
InputPrevious output
OutputStep 6 record
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn and re-check
Methods and standards
dimensional measurement and flaw detection
Confirm force, range and threshold against the applicable standard
Standards and applicability
GB/T 24762-2009
Configuration and service checks
Calibration and intermediate check records
Fixtures, accessories and range confirmation
Limitations
Family-level guidance, not a specific model capability
Re-confirm method and criteria outside the stated conditions
Search terms
几何计量
无损检测
自准直仪
精密运动控制
芯片测试
Related instruments, methods and research
Paper links indicate related methods or objects; they do not establish use of this instrument model.
Relation commonly used for this task
