Inputs

Example inputs: Micrometer reading=24.15 mm; Wire diameter=0.895 mm; Pitch=1.5 mm

Steps

Substitute and keep significant digits.

Result

See the default result in the linked calculator; values are illustrative.

Equation

d₂ = M − 3d₀ + 0.866P

Symbols & units

MMicrometer readingmm
d0Wire diametermm
PPitchmm