SHANGHAI MICROCRE OPTICS-MECH TECH CO., LTDAbout MICROCRE400-812-7833
MICROCRE · RESEARCH SCIENCE

Indentation size effect and load selection: complete workflow

Translation pending review.

Research track

performance

Research objective

Test plan for "Indentation size effect and load selection". Specimens of photovoltaic ribbon are measured under high-temperature oxidation in air at 900 °C following hardness testing. The plan fixes sampling, measurement parameters, acceptance basis and record format, and reports acquisition rate and synchronisation error with explicit limits of interpretation.

Objective

Obtain a reproducible acquisition rate and synchronisation error under high-temperature oxidation in air at 900 °C.

Required inputs

  • Specimen condition and batch

  • Calibration and range confirmation

  • Acceptance basis and record sheet

Workflow steps

  1. 01
    Title

    Fix the hardness scale and criterion

    Action

    Turn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.

    Input

    Output of the previous step and the environment log

    Output

    Step 1 record: acquisition rate and synchronisation error

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return to this step and re-check inputs and equipment

    Instruments for this step
  2. 02
    Title

    Prepare and inspect the surface

    Action

    Prepare specimens or measurement points for the material and purpose: grind and polish the surface without overheating or cold work; keep faces parallel and at least ten indentation depths thick.

    Input

    Output of the previous step and the environment log

    Output

    Step 2 record: acquisition rate and synchronisation error

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return to this step and re-check inputs and equipment

    Instruments for this step
  3. 03
    Title

    Verify test force and indenter

    Action

    Verify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.

    Input

    Output of the previous step and the environment log

    Output

    Step 3 record: acquisition rate and synchronisation error

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return to this step and re-check inputs and equipment

    Instruments for this step
  4. 04
    Title

    Space indents and measure

    Action

    Execute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.

    Input

    Output of the previous step and the environment log

    Output

    Step 4 record: acquisition rate and synchronisation error

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return to this step and re-check inputs and equipment

    Instruments for this step
  5. 05
    Title

    Handle outliers and statistics

    Action

    Judge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.

    Input

    Output of the previous step and the environment log

    Output

    Step 5 record: acquisition rate and synchronisation error

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return to this step and re-check inputs and equipment

    Instruments for this step
  6. 06
    Title

    Report values and decision

    Action

    Report method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.

    Input

    Output of the previous step and the environment log

    Output

    Step 6 record: acquisition rate and synchronisation error

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return to this step and re-check inputs and equipment

    Instruments for this step

Equations and variables

  • Item

    Oliver–Pharr 接触深度

    Equation

    h_c = h_max − ε · P_max / S

    Variables and units

    最大深度、峰值载荷、接触刚度、几何系数 ε

    Assumptions and limits

    按定义单位代入;测量条件稳定

    Worked example

    示例值仅用于演示代入过程

Worked example

Input parameters

Assumed inputs for photovoltaic ribbon under high-temperature oxidation in air at 900 °C

Calculation

Substitute step by step and keep significant digits

Result

Produces a teaching value, not an acceptance value

Limitations

Example excludes systematic equipment bias

Deliverables

  • Raw records and processing sheet

  • Result and uncertainty

Errors and risks

  • Measuring before the environment stabilises

  • Treating one batch as process capability evidence

Instrument applicability

Organised around the Hardness testers family in the catalogue; confirm model capability and accessories.

Required external capabilities

Preparation, loading or analysis equipment outside this catalogue may be required.

Literature scope

Literature links indicate related methods or objects, not use of our instruments.

Instrument roles in the workflow

Instrument familyRole and applicabilityWorkflow steps

Performs a measurement or preparation step

Verify test force and indenter · Space indents and measure

Performs a measurement or preparation step

Verify test force and indenter · Space indents and measure

Performs a measurement or preparation step

Verify test force and indenter · Space indents and measure

Language note

V9 结构化生成条目,发布前须由领域工程师复核技术细节。

Search terms

  • 检测方法

  • 标准规范

  • 选型方案

  • 科研流程

  • 模拟实验

Related instruments, methods and research

Paper links indicate related methods or objects; they do not establish use of this instrument model.

Your next research question. Let’s explore.

Tell us about your material, specimen and measurement goal.

Discuss your application ↗
Find your instrument
⌕
Search products, cases, solutions, standards and literature.