Straightness calibration of a precision stage: complete workflow
Translation pending review.
Research track
performance
Research objective
Test plan for "Straightness calibration of a precision stage". Specimens of 2024 aluminium riveted joint are measured under thermal shock at 300 K/s following small-angle and straightness measurement. The plan fixes sampling, measurement parameters, acceptance basis and record format, and reports die warpage and solder void rate with explicit limits of interpretation.
Objective
Obtain a reproducible die warpage and solder void rate under thermal shock at 300 K/s.
Required inputs
Specimen condition and batch
Calibration and range confirmation
Acceptance basis and record sheet
Workflow steps
- 01Title
Establish the datum and coordinate frame
ActionTurn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.
InputOutput of the previous step and the environment log
OutputStep 1 record: die warpage and solder void rate
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 02Title
Set the mirror and targets
ActionPrepare specimens or measurement points for the material and purpose: clean and thermally soak the datum, place the mirror or target along the travel, verify zero and bidirectional repeatability, then step at equal intervals.
InputOutput of the previous step and the environment log
OutputStep 2 record: die warpage and solder void rate
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 03Title
Verify zero and repeatability
ActionVerify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.
InputOutput of the previous step and the environment log
OutputStep 3 record: die warpage and solder void rate
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 04Title
Acquire angle or displacement in steps
ActionExecute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.
InputOutput of the previous step and the environment log
OutputStep 4 record: die warpage and solder void rate
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 05Title
Fit straightness and angular error
ActionJudge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.
InputOutput of the previous step and the environment log
OutputStep 5 record: die warpage and solder void rate
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 06Title
Assess environment and uncertainty
ActionReport method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.
InputOutput of the previous step and the environment log
OutputStep 6 record: die warpage and solder void rate
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
Equations and variables
- Item
斜率与角度换算
Equationθ = arctan(Δy/Δx) · 180/π
Variables and units高度差、水平距离
Assumptions and limits按定义单位代入;测量条件稳定
Worked example示例值仅用于演示代入过程
Worked example
Assumed inputs for 2024 aluminium riveted joint under thermal shock at 300 K/s
Substitute step by step and keep significant digits
Produces a teaching value, not an acceptance value
Example excludes systematic equipment bias
Deliverables
Raw records and processing sheet
Result and uncertainty
Errors and risks
Measuring before the environment stabilises
Treating one batch as process capability evidence
Instrument applicability
Organised around the Precision optics & autocollimation family in the catalogue; confirm model capability and accessories.
Required external capabilities
Preparation, loading or analysis equipment outside this catalogue may be required.
Literature scope
Literature links indicate related methods or objects, not use of our instruments.
Instrument roles in the workflow
| Instrument family | Role and applicability | Workflow steps |
|---|---|---|
Performs a measurement or preparation step | Verify zero and repeatability · Acquire angle or displacement in steps | |
Performs a measurement or preparation step | Verify zero and repeatability · Acquire angle or displacement in steps | |
Performs a measurement or preparation step | Verify zero and repeatability · Acquire angle or displacement in steps |
Language note
V9 结构化生成条目,发布前须由领域工程师复核技术细节。
Search terms
检测方法
标准规范
选型方案
科研流程
模拟实验
Related instruments, methods and research
Paper links indicate related methods or objects; they do not establish use of this instrument model.
