Cross-sectioning of battery electrodes: complete workflow
Translation pending review.
Research track
development
Research objective
Test plan for "Cross-sectioning of battery electrodes". Specimens of photovoltaic ribbon are measured under controlled 23±2 °C / 50±5 %RH following sectioning, mounting and polishing workflow. The plan fixes sampling, measurement parameters, acceptance basis and record format, and reports crack length and growth rate with explicit limits of interpretation.
Objective
Obtain a reproducible crack length and growth rate under controlled 23±2 °C / 50±5 %RH.
Required inputs
Specimen condition and batch
Calibration and range confirmation
Acceptance basis and record sheet
Workflow steps
- 01Title
Define the section plane and location
ActionTurn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.
InputOutput of the previous step and the environment log
OutputStep 1 record: crack length and growth rate
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 02Title
Select cutting process and cooling
ActionPrepare specimens or measurement points for the material and purpose: select the cut-off wheel and cooling by hardness and microstructure, then grind and polish stepwise with cleaning between steps to avoid smearing and relief.
InputOutput of the previous step and the environment log
OutputStep 2 record: crack length and growth rate
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 03Title
Mount and label the specimen
ActionVerify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.
InputOutput of the previous step and the environment log
OutputStep 3 record: crack length and growth rate
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 04Title
Grind and polish stepwise
ActionExecute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.
InputOutput of the previous step and the environment log
OutputStep 4 record: crack length and growth rate
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 05Title
Etch and inspect under the microscope
ActionJudge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.
InputOutput of the previous step and the environment log
OutputStep 5 record: crack length and growth rate
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
- 06Title
Record parameters and artefacts
ActionReport method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.
InputOutput of the previous step and the environment log
OutputStep 6 record: crack length and growth rate
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn to this step and re-check inputs and equipment
Equations and variables
- Item
工程应力
Equationσ = F / A₀
Variables and units载荷、原始横截面积
Assumptions and limits按定义单位代入;测量条件稳定
Worked example示例值仅用于演示代入过程
Worked example
Assumed inputs for photovoltaic ribbon under controlled 23±2 °C / 50±5 %RH
Substitute step by step and keep significant digits
Produces a teaching value, not an acceptance value
Example excludes systematic equipment bias
Deliverables
Raw records and processing sheet
Result and uncertainty
Errors and risks
Measuring before the environment stabilises
Treating one batch as process capability evidence
Instrument applicability
Organised around the Metallographic preparation family in the catalogue; confirm model capability and accessories.
Required external capabilities
Preparation, loading or analysis equipment outside this catalogue may be required.
Literature scope
Literature links indicate related methods or objects, not use of our instruments.
Instrument roles in the workflow
| Instrument family | Role and applicability | Workflow steps |
|---|---|---|
Performs a measurement or preparation step | Mount and label the specimen · Grind and polish stepwise | |
Performs a measurement or preparation step | Mount and label the specimen · Grind and polish stepwise | |
Performs a measurement or preparation step | Mount and label the specimen · Grind and polish stepwise |
Language note
V9 结构化生成条目,发布前须由领域工程师复核技术细节。
Search terms
检测方法
标准规范
选型方案
科研流程
模拟实验