Straightness of gantry grinder guideways, measured in segments

An 8 m guideway needs a straightness curve after assembly to guide scraping, with no temperature-controlled room and an instrument that can be moved between segments.

Industry:Machine toolsInstruments:MC030-1401 · MC030-LD400/68/0.5

The constraint

A spirit level gives local slope only, and a laser interferometer is sensitive to air flow and vibration on site.

Approach

An autocollimator with a plane mirror measures slope in 500 mm steps; the slopes are integrated into a full-length curve and closed at both ends.

  1. Place the mirror at the pitch, read in both directions, discard jumps from clamping
  2. Record each slope, integrate to a straightness curve, mark the maximum
  3. Set scraping allowance from the curve, re-measure and compare

Outcome

Full-length straightness improved from 0.06 mm to under 0.02 mm; the segment table became the release record for assembly.