SHANGHAI MICROCRE OPTICS-MECH TECH CO., LTDAbout MICROCRE400-812-7833
APPLICATION FILES

Application cases

Measurement scenarios by industry: workpiece, constraint, method combination and verification. Client details are anonymized.

Application scenario files: industry, workpiece type and measurement goals come from routine engineering discussions. Customer names and specific data are anonymized; nothing here is a traceable commercial record or a commitment about any customer's production results.

Automotive parts

Case depth and surface hardness on carburized gears

After carburizing and quenching, gear sets require surface hardness and a hardness profile on the same specimen to judge grinding allowance.

HVS-1000 · HRS-150 · ZMP-2000Z ↗
Aerospace

Coating thickness and microhardness across a turbine blade section

TBC and bond coat thickness plus interface hardness are repair criteria; thickness and indentation should be read in the same field of view.

HMAS-C1000SZA · MMAS-4 · ZMP-2000Z ↗
Bearing manufacturing

Inclusion rating and preparation consistency in bearing steel

Inclusion ratings for one heat differed between laboratories; preparation artefacts were suspected.

ZQ-30D · ZMP-2000Z · MMAS-19 ↗
Cutting tools & moulds

Coating adhesion and hardness profile on PVD-coated tools

Tool life varied widely; the customer needed to separate coating hardness from substrate heat treatment.

HVS-1000 · HMAS-C1000SZA · ZMP-2000Z ↗
Nuclear & pressure vessels

Weld HAZ hardness and microstructure review

Welding procedure qualification requires an HAZ hardness distribution matched to metallography to exclude embrittled structures.

HVS-1000 · MMAS-4 · ZQ-30D ↗
Rail transit

Wheel tread hardening depth and uniformity sampling

Depots need hardening-depth assessment on retired wheels to decide whether re-machining is viable.

HRS-150 · HVS-1000 · ZMP-2000Z ↗
Additive manufacturing

Density and microhardness versus process parameters in LPBF parts

Process-window trials need fast density and hardness feedback to shorten iteration.

ZMP-2000Z · MMAS-19 · HVS-1000 ↗
Medical devices

Surface layer thickness and hardness on orthopaedic implants

Modified surface layers must be evaluated without damaging the functional face.

HMAS-C1000SZA · MMAS-4 · ZMP-2000Z ↗
Semiconductor & electronics

Thickness uniformity and interface hardness of thin films

Film thickness differed between wafer centre and edge; the cause could be process drift or measurement bias.

HMAS-C1000SZA · MMAS-4 · ZMP-2000Z ↗
Steel & metallurgy

Specimen orientation consistency for plate tensile and impact

Mechanical data scattered across orientations in one plate batch; orientation and machining quality needed checking.

YRWT-M · ZQ-30D · HVS-1000 ↗
Non-ferrous metals & copper foil

In-line roughness and thickness sampling of battery copper foil

Foil is a few micrometres thick and roughness drives coating adhesion, so fast sampling matters.

Y9025B · MMAS-19 · ZMP-2000Z ↗
Mould making

Mould surface hardness uniformity and weld repair re-check

Hardness varied across a large mould face; data were needed on softened zones at weld repairs.

HRS-150 · HVS-1000 · MMAS-4 ↗
Third-party laboratories

Preparation and testing throughput for high-mix low-volume samples

Daily samples of mixed materials made preparation the bottleneck.

ZMP-2000Z · ZQ-30D · MMAS-19 ↗
Universities & institutes

Multilingual operation and data standards in materials teaching labs

International and local students shared instruments with inconsistent procedures and data formats.

HVS-1000 · MMAS-4 · ZMP-2000Z ↗
Battery manufacturing

Electrode coating thickness and post-calendering hardness

Coating thickness variation affects capacity consistency; calendering uniformity also needs checking.

Y9025B · HVS-1000 · ZMP-2000Z ↗
Machine tools

Straightness of gantry grinder guideways, measured in segments

An 8 m guideway needs a straightness curve after assembly to guide scraping, with no temperature-controlled room and an instrument that can be moved b…

MC030-1401 · MC030-LD400/68/0.5 ↗
Precision optics and metrology

Calibrating the indexing error of a precision rotary table

A rotary table used for optical assembly must be checked every 15° to confirm angular margin for mirror-group alignment.

MC030-1401 · 1401-15 ↗
Heat treatment and metallography

Removing sectioning burn from case-depth judgement

Case depth on the same batch differed by 0.1 mm between laboratories; the cause had to be traced to preparation or material.

ZXG-100 · XQ-2B · ZMP-2000Z ↗
Coatings and surface engineering

Vacuum mounting and edge retention for porous thermal-spray coatings

Porous sprayed coatings absorb little resin in normal mounting, so edges collapse during polishing and thickness reads low.

XQ-2B · MPD-2A · MMAS-4 ↗
Pressure vessels and low-temperature structures

Building a ductile-brittle transition curve

Tank steel needs Charpy energy at −40 ℃ and a transition range to set the minimum service temperature.

JB-300B500B · ZMP-2000Z ↗
Composites

In-plane tension of continuous-fibre composites

A laminate needs 0° and 90° tensile modulus and strength to check the lay-up design.

WDW-300M ↗
Advanced ceramics

Hot hardness of structural ceramics at 1200 ℃

SiC-alumina composites need hardness at 1200 ℃ for wear-part material selection.

HMAS-HT1200 ↗
Aero engines

Indentation creep of a Ni-based superalloy at 1000 ℃

Single-crystal blade alloys must be compared across heat treatments near service temperature with limited material.

HMAS-HT1300CM ↗
Copper and copper alloys

Grain size of copper strip by intercept counting

Lead-frame copper strip needs a grain-size rating to confirm anneal stability.

MMAS-4 · 4XC · ZMP-2000Z ↗
Electronics and precision parts

Microhardness of 0.1 mm sheet with edge protection

A 0.1 mm spring strip needs cross-sectional hardness, but curls easily and loses perpendicularity after normal mounting.

HVS-1000Z · XQ-2B · ZMP-2000Z ↗
Surface treatment

Microscopic section measurement of anodised layers

Anodised aluminium needs local thickness; eddy-current readings scatter on curved surfaces, so a section check is needed.

ZXG-100 · XQ-2B · MMAS-4 ↗
Casting and incoming inspection

Spectral verification of cast aluminium incoming lots

Each aluminium ingot lot needs major and trace element checks for release, with one operator and under three minutes per piece.

YR-9000 ↗

Your next research question. Let’s explore.

Tell us about your material, specimen and measurement goal.

Discuss your application ↗
Find your instrument
⌕
Search products, cases, solutions, standards and literature.