APPLICATION FILE / Composites
In-plane tension of continuous-fibre composites
A laminate needs 0° and 90° tensile modulus and strength to check the lay-up design.
The constraint
Grip ends concentrate stress and fail early, and extensometer knives can damage the surface.
Approach
Bond tabs, control grip pressure and measure strain in the middle section with a large-deformation extensometer at the standard rate.
- Bond gauges or fit the extensometer with the gauge length centred
- Load at 2 mm/min to failure and record curve features
- Compute modulus and strength per fibre direction and note failure modes
Outcome
0° modulus was within 4% of design while 90° strength fell short, prompting a lay-up change.
Related instruments