SHANGHAI MICROCRE OPTICS-MECH TECH CO., LTDAbout MICROCRE400-812-7833
MICROCRE · RESEARCH SCIENCE

光谱制样与电解抛光 — Avoiding hydrogen pickup in titanium preparation

A schematic of the measurement chain, not device footage or data.

Schematic demonstration: scale, speed and colour do not represent instrument measurements.

Translation pending review.

Instrument role

Measurement and analysis

Operating principle

Principle summary

For this task the 光谱制样与电解抛光 family measures as follows: Avoiding hydrogen pickup in titanium preparation. The general relation and its conditions are given below; confirm force, travel, resolution and accessories for a specific model.

Equation

R_p0.2 = σ₁ + (0.2 − ε₁)/(ε₂ − ε₁) · (σ₂ − σ₁)

Variables and units
  • Symbol

    s1

    Item

    Lower stress

    Unit

    MPa

  • Symbol

    e1

    Item

    Lower strain

    Unit

    %

  • Symbol

    s2

    Item

    Upper stress

    Unit

    MPa

  • Symbol

    e2

    Item

    Upper strain

    Unit

    %

Assumptions and limits
  • Conditions are stable and calibrated as defined

  • Inputs are independent without unmodelled bias

  • Interpretation stays within this family and the stated conditions

Research objects

  • Research object: AlSi10Mg die-cast aluminium

  • Research object: 7075 aluminium alloy

  • Research object: 2024 aluminium riveted joint

Research questions

  • What dominates the error budget for Avoiding hydrogen pickup in titanium preparation?

  • Does the conclusion hold for another batch or process?

Applications

  • Avoiding hydrogen pickup in titanium preparation: AlSi10Mg die-cast aluminium

  • Avoiding hydrogen pickup in titanium preparation: 7075 aluminium alloy

From specimen to result

  1. 01
    Title

    Define the section plane and location

    Action

    Turn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.

    Input

    Previous output

    Output

    Step 1 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  2. 02
    Title

    Select cutting process and cooling

    Action

    Prepare specimens or measurement points for the material and purpose: select the cut-off wheel and cooling by hardness and microstructure, then grind and polish stepwise with cleaning between steps to avoid smearing and relief.

    Input

    Previous output

    Output

    Step 2 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  3. 03
    Title

    Mount and label the specimen

    Action

    Verify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.

    Input

    Previous output

    Output

    Step 3 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step
  4. 04
    Title

    Grind and polish stepwise

    Action

    Execute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.

    Input

    Previous output

    Output

    Step 4 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  5. 05
    Title

    Etch and inspect under the microscope

    Action

    Judge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.

    Input

    Previous output

    Output

    Step 5 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  6. 06
    Title

    Record parameters and artefacts

    Action

    Report method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.

    Input

    Previous output

    Output

    Step 6 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step

Methods and standards

  • sectioning, mounting and polishing workflow

  • Confirm force, range and threshold against the applicable standard

Configuration and service checks

  • Calibration and intermediate check records

  • Fixtures, accessories and range confirmation

Limitations

  • Family-level guidance, not a specific model capability

  • Re-confirm method and criteria outside the stated conditions

Search terms

  • 金相制样

  • DIC

  • 散斑

  • 离子束

  • 电子束

  • 仪器全自动化

  • 自动制样

Related instruments, methods and research

Paper links indicate related methods or objects; they do not establish use of this instrument model.

Relation commonly used for this task

Your next research question. Let’s explore.

Tell us about your material, specimen and measurement goal.

Discuss your application ↗
Find your instrument
⌕
Search products, cases, solutions, standards and literature.