测厚仪 — Magnetic particle and penetrant testing
A schematic of the measurement chain, not device footage or data.
Schematic demonstration: scale, speed and colour do not represent instrument measurements.
Translation pending review.
Instrument role
Measurement and analysis
Operating principle
For this task the 测厚仪 family measures as follows: Magnetic particle and penetrant testing. The general relation and its conditions are given below; confirm force, travel, resolution and accessories for a specific model.
t = k · (N₁ − N₀)
- Symbol
k
ItemCalibration slope
Unitµm/1
- Symbol
N1
ItemReading on coating
Unit1
- Symbol
N0
ItemSubstrate zero
Unit1
Conditions are stable and calibrated as defined
Inputs are independent without unmodelled bias
Interpretation stays within this family and the stated conditions
Research objects
Research object: 45 carbon steel
Research object: 42CrMo quenched and tempered steel
Research object: 20CrMnTi carburising steel
Research questions
What dominates the error budget for Magnetic particle and penetrant testing?
Does the conclusion hold for another batch or process?
Applications
Magnetic particle and penetrant testing: 45 carbon steel
Magnetic particle and penetrant testing: 42CrMo quenched and tempered steel
From specimen to result
- 01Title
Read the drawing, datum and tolerance
ActionTurn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.
InputPrevious output
OutputStep 1 record
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn and re-check
- 02Title
Clean and thermally soak the part
ActionPrepare specimens or measurement points for the material and purpose: soak to 20 °C and clean the surface, establish the datum and frame, calibrate the probe, then choose points and evaluation rules from the drawing.
InputPrevious output
OutputStep 2 record
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn and re-check
- 03Title
Calibrate probe or transducer
ActionVerify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.
InputPrevious output
OutputStep 3 record
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn and re-check
- 04Title
Acquire points as planned
ActionExecute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.
InputPrevious output
OutputStep 4 record
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn and re-check
- 05Title
Fit features and evaluate tolerance
ActionJudge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.
InputPrevious output
OutputStep 5 record
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn and re-check
- 06Title
Review outliers and report
ActionReport method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.
InputPrevious output
OutputStep 6 record
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn and re-check
Methods and standards
dimensional measurement and flaw detection
Confirm force, range and threshold against the applicable standard
Standards and applicability
GB/T 4956-2003
GB/T 4957-2003
GB/T 11374-2012
Configuration and service checks
Calibration and intermediate check records
Fixtures, accessories and range confirmation
Limitations
Family-level guidance, not a specific model capability
Re-confirm method and criteria outside the stated conditions
Search terms
几何计量
无损检测
自准直仪
精密运动控制
芯片测试
Related instruments, methods and research
Paper links indicate related methods or objects; they do not establish use of this instrument model.
Relation commonly used for this task