SHANGHAI MICROCRE OPTICS-MECH TECH CO., LTDAbout MICROCRE400-812-7833
MICROCRE · RESEARCH SCIENCE

布洛维硬度计 — Indentation size effect and load selection

A schematic of the measurement chain, not device footage or data.

Schematic demonstration: scale, speed and colour do not represent instrument measurements.

Translation pending review.

Instrument role

Measurement and analysis

Operating principle

Principle summary

For this task the 布洛维硬度计 family measures as follows: Indentation size effect and load selection. The general relation and its conditions are given below; confirm force, travel, resolution and accessories for a specific model.

Equation

A(h_c) = C₀h_c² + C₁h_c + C₂h_c^0.5

Variables and units
  • Symbol

    hc

    Item

    Contact depth

    Unit

    nm

  • Symbol

    C0

    Item

    Quadratic term

    Unit

    nm²/nm²

  • Symbol

    C1

    Item

    Linear term

    Unit

    nm

  • Symbol

    C2

    Item

    Square-root term

    Unit

    nm^1.5

Assumptions and limits
  • Conditions are stable and calibrated as defined

  • Inputs are independent without unmodelled bias

  • Interpretation stays within this family and the stated conditions

Research objects

  • Research object: GCr15 bearing steel

  • Research object: H13 hot-work tool steel

  • Research object: DC53 cold-work die steel

Research questions

  • What dominates the error budget for Indentation size effect and load selection?

  • Does the conclusion hold for another batch or process?

Applications

  • Indentation size effect and load selection: GCr15 bearing steel

  • Indentation size effect and load selection: H13 hot-work tool steel

From specimen to result

  1. 01
    Title

    Fix the hardness scale and criterion

    Action

    Turn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.

    Input

    Previous output

    Output

    Step 1 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  2. 02
    Title

    Prepare and inspect the surface

    Action

    Prepare specimens or measurement points for the material and purpose: grind and polish the surface without overheating or cold work; keep faces parallel and at least ten indentation depths thick.

    Input

    Previous output

    Output

    Step 2 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  3. 03
    Title

    Verify test force and indenter

    Action

    Verify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.

    Input

    Previous output

    Output

    Step 3 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step
  4. 04
    Title

    Space indents and measure

    Action

    Execute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.

    Input

    Previous output

    Output

    Step 4 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  5. 05
    Title

    Handle outliers and statistics

    Action

    Judge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.

    Input

    Previous output

    Output

    Step 5 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  6. 06
    Title

    Report values and decision

    Action

    Report method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.

    Input

    Previous output

    Output

    Step 6 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step

Methods and standards

  • hardness testing

  • Confirm force, range and threshold against the applicable standard

Standards and applicability

  • GB/T 230.1-2018

  • GB/T 230.2-2022

  • GB/T 231.1-2018

  • GB/T 4340.1-2009

  • GB/T 9790-2021

Configuration and service checks

  • Calibration and intermediate check records

  • Fixtures, accessories and range confirmation

Limitations

  • Family-level guidance, not a specific model capability

  • Re-confirm method and criteria outside the stated conditions

Search terms

  • 高温压痕

  • 采集频率

  • 100Hz

  • 仪器全自动化

  • 升级改造

  • 氧化腐蚀

  • AI

  • 材料性能预测

  • 硬度计

Related instruments, methods and research

Paper links indicate related methods or objects; they do not establish use of this instrument model.

Relation commonly used for this task

Your next research question. Let’s explore.

Tell us about your material, specimen and measurement goal.

Discuss your application ↗
Find your instrument
⌕
Search products, cases, solutions, standards and literature.