SHANGHAI MICROCRE OPTICS-MECH TECH CO., LTDAbout MICROCRE400-812-7833
MICROCRE · RESEARCH SCIENCE

超高温与原位压痕 — Strength retention of Cf/SiC at high temperature

A schematic of the measurement chain, not device footage or data.

Schematic demonstration: scale, speed and colour do not represent instrument measurements.

Translation pending review.

Instrument role

Measurement and analysis

Operating principle

Principle summary

For this task the 超高温与原位压痕 family measures as follows: Strength retention of Cf/SiC at high temperature. The general relation and its conditions are given below; confirm force, travel, resolution and accessories for a specific model.

Equation

h_f / h_max = 1 − ε·P/(S·h_max)

Variables and units
  • Symbol

    eps

    Item

    Geometric factor

    Unit

    1

  • Symbol

    pmax

    Item

    Peak load

    Unit

    mN

  • Symbol

    S

    Item

    Contact stiffness

    Unit

    mN/nm

  • Symbol

    hmax

    Item

    Maximum depth

    Unit

    nm

Assumptions and limits
  • Conditions are stable and calibrated as defined

  • Inputs are independent without unmodelled bias

  • Interpretation stays within this family and the stated conditions

Research objects

  • Research object: 2205 duplex stainless steel

  • Research object: TC4 titanium alloy

  • Research object: TA15 titanium alloy

Research questions

  • What dominates the error budget for Strength retention of Cf/SiC at high temperature?

  • Does the conclusion hold for another batch or process?

Applications

  • Strength retention of Cf/SiC at high temperature: 2205 duplex stainless steel

  • Strength retention of Cf/SiC at high temperature: TC4 titanium alloy

From specimen to result

  1. 01
    Title

    Define the environment envelope and coupled fields

    Action

    Turn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.

    Input

    Previous output

    Output

    Step 1 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  2. 02
    Title

    Check thermal match of system and specimen

    Action

    Prepare specimens or measurement points for the material and purpose: confirm the temperature limits of furnace, grips, sensors and specimen, evacuate or purge and stabilise before loading, and control heating and cooling rates.

    Input

    Previous output

    Output

    Step 2 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  3. 03
    Title

    Establish vacuum or atmosphere

    Action

    Verify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.

    Input

    Previous output

    Output

    Step 3 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step
  4. 04
    Title

    Ramp and stabilise temperature

    Action

    Execute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.

    Input

    Previous output

    Output

    Step 4 record

    Quality gate

    The acceptance basis traces to a standard clause or technical agreement

    If the check fails

    Return and re-check

    Instruments for this step
  5. 05
    Title

    Load and acquire multi-field signals

    Action

    Judge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.

    Input

    Previous output

    Output

    Step 5 record

    Quality gate

    Environmental conditions and stabilisation time are logged continuously

    If the check fails

    Return and re-check

    Instruments for this step
  6. 06
    Title

    Assess environment-induced bias

    Action

    Report method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.

    Input

    Previous output

    Output

    Step 6 record

    Quality gate

    Raw data, processing and the decision are reproducible

    If the check fails

    Return and re-check

    Instruments for this step

Methods and standards

  • extreme-environment testing

  • Confirm force, range and threshold against the applicable standard

Standards and applicability

  • GB/T 21838.1-2008

  • GB/T 21838.2-2008

  • GB/T 10592-2023

  • GB/T 2423.22-2012

  • GJB 150.3A-2009

Configuration and service checks

  • Calibration and intermediate check records

  • Fixtures, accessories and range confirmation

Limitations

  • Family-level guidance, not a specific model capability

  • Re-confirm method and criteria outside the stated conditions

Search terms

  • 真空

  • 超真空

  • 真空热循环

  • 热冲击

  • 高温高压

  • 液氮

  • 液氦

  • 氧化腐蚀

  • 高温氧化

  • 多气氛

  • 空间环境

  • 深空

  • 航空航天

  • 多物理场

  • SHPB

  • 霍普金森

  • 高速疲劳

  • 卫星

  • 空间发动机

  • 辐射

  • 低温力学

  • 燃气腐蚀

Related instruments, methods and research

Relation commonly used for this task

Your next research question. Let’s explore.

Tell us about your material, specimen and measurement goal.

Discuss your application ↗
Find your instrument
⌕
Search products, cases, solutions, standards and literature.