金相试样切割机 — Distortion-free sectioning of sheet and foil
A schematic of the measurement chain, not device footage or data.
Schematic demonstration: scale, speed and colour do not represent instrument measurements.
Translation pending review.
Instrument role
Measurement and analysis
Operating principle
For this task the 金相试样切割机 family measures as follows: Distortion-free sectioning of sheet and foil. The general relation and its conditions are given below; confirm force, travel, resolution and accessories for a specific model.
d = d₁ + (H₁ − 550)/(H₁ − H₂) · (d₂ − d₁)
- Symbol
d1
ItemUpper depth
Unitmm
- Symbol
d2
ItemLower depth
Unitmm
- Symbol
H1
ItemUpper hardness
UnitHV
- Symbol
H2
ItemLower hardness
UnitHV
Conditions are stable and calibrated as defined
Inputs are independent without unmodelled bias
Interpretation stays within this family and the stated conditions
Research objects
Research object: TA15 titanium alloy
Research object: GH4169 nickel-based superalloy
Research object: Inconel 718 additively manufactured part
Research questions
What dominates the error budget for Distortion-free sectioning of sheet and foil?
Does the conclusion hold for another batch or process?
Applications
Distortion-free sectioning of sheet and foil: TA15 titanium alloy
Distortion-free sectioning of sheet and foil: GH4169 nickel-based superalloy
From specimen to result
- 01Title
Define the section plane and location
ActionTurn the task into verifiable measurands: state which standard or technical agreement defines %s, and fix the record fields.
InputPrevious output
OutputStep 1 record
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn and re-check
- 02Title
Select cutting process and cooling
ActionPrepare specimens or measurement points for the material and purpose: select the cut-off wheel and cooling by hardness and microstructure, then grind and polish stepwise with cleaning between steps to avoid smearing and relief.
InputPrevious output
OutputStep 2 record
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn and re-check
- 03Title
Mount and label the specimen
ActionVerify calibration status, fixtures and sensor ranges against the environmental envelope; complete the uncertainty budget before measuring.
InputPrevious output
OutputStep 3 record
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn and re-check
- 04Title
Grind and polish stepwise
ActionExecute the fixed method with identical parameters; stabilise the environment within the specified time and log any abnormal condition separately.
InputPrevious output
OutputStep 4 record
Quality gateThe acceptance basis traces to a standard clause or technical agreement
If the check failsInstruments for this stepReturn and re-check
- 05Title
Etch and inspect under the microscope
ActionJudge the main value, outliers and repeatability; keep raw records for any rejected point and state the basis instead of deleting it.
InputPrevious output
OutputStep 5 record
Quality gateEnvironmental conditions and stabilisation time are logged continuously
If the check failsInstruments for this stepReturn and re-check
- 06Title
Record parameters and artefacts
ActionReport method, conditions, results, uncertainty and applicability limits; do not extrapolate beyond the tested environment.
InputPrevious output
OutputStep 6 record
Quality gateRaw data, processing and the decision are reproducible
If the check failsInstruments for this stepReturn and re-check
Methods and standards
sectioning, mounting and polishing workflow
Confirm force, range and threshold against the applicable standard
Standards and applicability
GB/T 13298-2015
GB/T 226-2015
GB/T 1979-2001
GB/T 3246.2-2012
ASTM E3-11
Configuration and service checks
Calibration and intermediate check records
Fixtures, accessories and range confirmation
Limitations
Family-level guidance, not a specific model capability
Re-confirm method and criteria outside the stated conditions
Search terms
金相制样
DIC
散斑
离子束
电子束
仪器全自动化
自动制样
Related instruments, methods and research
Paper links indicate related methods or objects; they do not establish use of this instrument model.
Relation commonly used for this task